Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-05-16 05:10 CEST


Basic data
Code: XMOUA
Old ISKO number: 1632
Locality: Mobilni vuz Usti1
Type of measuring programme: Automated measuring program
Measuring networks: National air pollution monitoring network
Administrator
ČHMÚ-pobočka Ústí n/Labem
Pošt. přihrádka 2
40011 Ústí n/Labem
Tel.: 472 706 053
 
E-mail: petr.goll@chmi.cz
Target of the measuring programme
Cover
air-conditioned mobile container
Note
Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg/m³ Yes Yes 0 N N A N R N 1h 2006-01-13 2020-12-31
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg/m³ Yes Yes 0 N N A N R N 10min 2006-01-13 2020-12-31
L1 D1 18 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 N A A N R N 1h 2006-01-13 2020-12-31
L1 D1 18 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 N A A N R N 1h 2006-01-13 2020-12-31
L1 D1 18 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 N A A N R N 1h 2006-01-13 2020-12-31
L1 D1 20 CO [carbon monoxide] - IRABS [IR corel. absorption spectrometry] µg/m³ Yes Yes 0 N N A N R N 1h 2006-01-13 2020-12-31
L1 D1 22 O₃ [ozone] - UVABS [UV-absorption] µg/m³ Yes Yes 0 N A A N R N 1h 2006-01-13 2020-12-31
L1 D1 26 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] µg/m³ Yes Yes 0 Y N A A A N 1h 2006-01-13 2020-12-31
L1 D1 30 BZN [Benzene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes Yes 0 N A A N R N 1h 2006-01-13 2020-12-31
L1 D1 30 TLN [toluene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes Yes 0 N A A N R N 1h 2006-01-13 2020-12-31
L1 D1 30 EBZN [ethylbenzene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes No 0 Y N N N N N 1h 2006-01-13 2009-12-31
L1 D1 30 MPXY [m,p-xylene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes No 0 Y N N N N N 1h 2006-01-13 2009-12-31
L1 D1 30 OXY [o-xylene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes No 0 Y N N N N N 1h 2006-01-13 2009-12-31
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] m/s Yes Yes 0 N N A N N N 1h 2006-01-13 2020-12-31
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] m/s Yes Yes 0 N N A N N N 10min 2006-01-13 2020-12-31
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] deg Yes Yes 0 N N A N N N 1h 2006-01-13 2020-12-31
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] deg Yes Yes 0 N N A N N N 10min 2006-01-13 2020-12-31
L1 D1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] m/s Yes Yes 0 N N A N N N 1h 2007-01-01 2020-12-31
L1 D1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] m/s Yes Yes 0 N N A N N N 10min 2008-10-15 2020-12-31
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] deg Yes Yes 0 N N A N N N 1h 2007-01-01 2020-12-31
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] deg Yes Yes 0 N N A N N N 10min 2008-10-15 2020-12-31
L1 D1 46 p [atmospheric pressure] - APRESS [atmospheric pressure measurement] hPa No No 0 N N N N N N 1h 2006-01-13 2009-12-31
L1 D1 41 h [relative air humidity (h. of air)] - CAP [capacitance sensor] % Yes Yes 0 N N A N N N 1h 2006-01-13 2020-12-31
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] W/m 2 Yes Yes 0 N N A N N N 1h 2006-01-13 2020-12-31
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] W/m 2 Yes Yes 0 N N A N N N 10min 2006-01-13 2020-12-31
L1 D1 41 T2m [temperature 2m above terrain] - PT100 [resistance method] K Yes Yes 0 N N A N N N 1h 2006-01-13 2020-12-31
List of laboratories
Laboratory number 1 (L1) CHMI-Usti n/L AIM
pošt. přihrádka 2
400 11 Ústí nad Labem
Tel.: 472 706 053
 
E-mail: petr.goll@chmi.cz
List of data suppliers
Supplier number 1 (D1) ČHMÚ-pobočka Ústí n/Labem-AIM
Pošt. přihrádka 2
40011 Ústí nad Labem
Tel.: 472 706 053
 
E-mail: petr.goll@chmi.cz