Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-02-21 03:46 CET


Basic data
Code: UMRTA
Old ISKO number: 1034
Locality: Martineves
Type of measuring programme: Automated measuring program
Measuring networks:
Administrator
ČHMÚ-pobočka Ústí n/Labem
Pošt. přihrádka 2
40011 Ústí n/Labem
Tel.: 472 706 053
 
E-mail: petr.goll@chmi.cz
Target of the measuring programme
Evalution of total level of concentrations beckground
Cover
not defined
Note
Na rovině za vesnicí vedle vodojemu na kraji pole. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
1 1 0 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg/m³ No No 0 N N N N N N 30min 1993-05-21 2003-04-22
1 1 0 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m³ No No 0 N N N N N N 30min 1993-05-21 2003-04-22
1 1 0 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] µg/m³ No No 0 N N N N N N 30min 1993-05-21 2003-04-22
1 1 0 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] µg/m³ No No 0 N N N N N N 30min 1993-05-21 2003-04-22
1 1 0 O₃ [ozone] - UVABS [UV-absorption] µg/m³ No No 0 N N N N N N 30min 2002-05-01 2003-04-22
1 1 0 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] µg/m³ No No 0 N N N N N N 30min 1995-10-20 2003-04-22
1 1 0 SPM [suspended particulate matter] - RADIO [radiometry - beta ray absorption] µg/m³ No No 0 N N N N N N 30min 1993-05-21 1995-10-19
1 1 0 WV [wind velocity] - OPEL [optoelectronic method] m/s No No 0 N N N N N N 30min 1995-01-01 2003-04-22
1 1 0 WD [wind direction] - OPEL [optoelectronic method] deg No No 0 N N N N N N 30min 1995-01-01 2003-04-22
1 1 0 p [atmospheric pressure] - APRESS [atmospheric pressure measurement] hPa No No 0 N N N N N N 30min 1995-01-01 2003-04-22
1 1 0 h [relative air humidity (h. of air)] - SKIN [animal skin] % No No 0 N N N N N N 30min 1995-01-01 1997-04-22
1 1 0 h [relative air humidity (h. of air)] - CAP [capacitance sensor] % No No 0 N N N N N N 30min 1997-04-23 2003-04-22
1 1 0 GLRD [global radiation] - TDM [temperature difference method] W/m 2 No No 0 N N N N N N 30min 1995-01-01 2003-04-22
1 1 0 T2m [temperature 2m above terrain] - PT100 [resistance method] K No No 0 N N N N N N 30min 1995-01-01 2003-04-22
List of laboratories
Laboratory number 1 ČHMÚ-pobočka Ústi n/Labem
Kočkovská 18
40011 Ústi n/Labem
Tel.: 472706050
 
E-mail: petra.mrazova@chmi.cz
List of data suppliers
Supplier number 1 ČHMÚ-pobočka Ústí n/Labem-AIM
Pošt. přihrádka 2
40011 Ústí nad Labem
Tel.: 472 706 053
 
E-mail: petr.goll@chmi.cz