Information about air quality in the Czech Republic
Measuring programme table
Updated: 2024-04-23 04:52 CEST
Basic data | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code: | UBINA | |||||||||||||||||
Old ISKO number: | 1226 | |||||||||||||||||
Locality: | Bilina | |||||||||||||||||
Type of measuring programme: | Automated measuring program | |||||||||||||||||
Measuring networks: | ||||||||||||||||||
Administrator | ||||||||||||||||||
ZÚ se sídlem v ÚL-obl.prac.Teplice
Wolkerova 3 41501 Teplice v Č. |
Tel.: 477751740 | |||||||||||||||||
E-mail: ivan.benes@zuusti.cz | ||||||||||||||||||
Target of the measuring programme | ||||||||||||||||||
Cover | ||||||||||||||||||
not defined | ||||||||||||||||||
Note | ||||||||||||||||||
Stanice ve městě, umístěna na parkovišti na náměstí na mírném svahu, okolo frekv. městská komunikace, nižší domky, cca 100m vysoký panelový dům. Stanice v majetku OHS Teplice, ČHMÚ pouze provozovatelem. Typ stanice změněn k 12/2001 - silnice přeložena. | ||||||||||||||||||
Measurements | ||||||||||||||||||
Lab. | Supp. | Instr. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Acc. | ICT | Met. tr. | Valid. | Tests ek. | Uncert. | Interval | Date of start | Date of end |
L1 | D1 | 0 | SO₂ [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m³ | No | No | 0 | N | N | N | N | N | N | 30min | 1995-01-01 | 1999-03-31 |
L1 | D1 | 0 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m³ | No | No | 0 | N | N | N | N | N | N | 30min | 1995-01-01 | 1999-03-31 |
L1 | D1 | 0 | NO₂ [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m³ | No | No | 0 | N | N | N | N | N | N | 30min | 1995-01-01 | 1999-03-31 |
L1 | D1 | 0 | NOₓ [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m³ | No | No | 0 | N | N | N | N | N | N | 30min | 1995-01-01 | 1999-03-31 |
L1 | D1 | 0 | CO [carbon monoxide] | - | IRABS [IR corel. absorption spectrometry] | µg/m³ | No | No | 0 | N | N | N | N | N | N | 30min | 1995-01-01 | 1999-03-31 |
L1 | D1 | 0 | O₃ [ozone] | - | UVABS [UV-absorption] | µg/m³ | No | No | 0 | N | N | N | N | N | N | 30min | 1995-01-01 | 1999-03-31 |
L1 | D1 | 0 | PM₁₀ [particles PM10] | - | RADIO [radiometry - beta ray absorption] | µg/m³ | No | No | 0 | N | N | N | N | N | N | 30min | 1995-01-01 | 1999-03-31 |
L1 | D1 | 0 | WV [wind velocity] | - | ELMAG [electromagnetic method] | m/s | No | No | 0 | N | N | N | N | N | N | 30min | 1995-01-01 | 1999-03-31 |
L1 | D1 | 0 | WD [wind direction] | - | OPEL [optoelectronic method] | deg | No | No | 0 | N | N | N | N | N | N | 30min | 1995-01-01 | 1999-03-31 |
L1 | D1 | 0 | p [atmospheric pressure] | - | APRESS [atmospheric pressure measurement] | hPa | No | No | 0 | N | N | N | N | N | N | 30min | 1995-01-01 | 1999-03-31 |
L1 | D1 | 0 | h [relative air humidity (h. of air)] | - | HAIR [hair hygrometer] | % | No | No | 0 | N | N | N | N | N | N | 30min | 1995-01-01 | 1999-03-31 |
L1 | D1 | 0 | GLRD [global radiation] | - | TDM [temperature difference method] | W/m 2 | No | No | 0 | N | N | N | N | N | N | 30min | 1995-01-01 | 1999-03-31 |
L1 | D1 | 0 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | No | No | 0 | N | N | N | N | N | N | 30min | 1995-01-01 | 1999-03-31 |
L1 | D1 | 0 | T10m [temperature 10m above terrain] | - | PT100 [resistance method] | K | No | No | 0 | N | N | N | N | N | N | 30min | 1995-01-01 | 1999-03-31 |
List of laboratories | ||||||||||||||||||
Laboratory number 1 |
ZÚ se sídlem v ÚL-obl.prac.Teplice
Wolkerova 3 41501 Teplice |
Tel.: 477751740 | ||||||||||||||||
E-mail: ivan.benes@zuusti.cz | ||||||||||||||||||
List of data suppliers | ||||||||||||||||||
Supplier number 1 |
ZÚ se sídlem v ÚL-obl.prac.Teplice
Wolkerova 3 41501 Teplice |
Tel.: 477751740 | ||||||||||||||||
E-mail: ivan.benes@zuusti.cz |