Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-04-23 04:52 CEST


Basic data
Code: TOPOM
Old ISKO number: 125
Locality: Ostrava-Poruba CHMU
Type of measuring programme: Manual measuring program
Measuring networks: National air pollution monitoring network
Administrator
ČHMÚ - pob.Ostrava
K Myslivně 3/2182
70800 Ostrava - Poruba
Tel.: 596 900 218
 
E-mail: blanka.krejci@chmi.cz
Target of the measuring programme
Evalution of concentration in urban areas
Cover
measuring box (heated), sampler (situated separately)
Note
K jihu mírně skloněný pozemek pobočky ČHMÚ Ostrava, původně dobrá otevřená lokalita, klimatologická stanice ČHMÚ. Od 1.1.1997 u měření SPM přechod na filtry průměr 50mm. Od ledna 1999 je v blízkosti stanice benzínová pumpa a pokračuje zde stavební činnost.
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 55 PM₂.₅ [fine particles PM2.5] LVSman2.3 [LVS - manual filter change 2,3 m3/h] GRV [gravimetry] µg/m³ Yes No 0 Y A A A R A 1d 2003-07-01
L1 D1 55 PM₁₀ [particles PM10] LVSman2.3 [LVS - manual filter change 2,3 m3/h] GRV [gravimetry] µg/m³ Yes No 0 Y A A A R A 1d 2003-01-01
L2 D2 1 SO₂ [sulphur dioxide] - WGAE [West-Gaeke spectrophotometry] µg/m³ No No 1 N N N N N N 1d 1977-01-01 1988-12-31
L2 D2 1 SO₂ [sulphur dioxide] - WGAE [West-Gaeke spectrophotometry] µg/m³ No No 0 N N N N N N 1d 1970-01-01 2003-03-31
L2 D3 2 SO₂ [sulphur dioxide] - IC [ion chromatography] µg/m³ Yes No 0 Y N N N N N 1d 2003-04-01 2012-12-31
L2 D3 2 SO₂ [sulphur dioxide] - IC [ion chromatography] µg/m³ Yes No 1 Y N N N N N 1d 2004-01-01 2012-12-31
L2 D2 5 NO₂ [nitrogen dioxide] - GUAJA [guajacol (modif. Jakobs-Hochheiser) - spectrophotometry] µg/m³ No No 0 N N N N N N 1d 1997-01-01 1997-12-31
L1 D1 5 NO₂ [nitrogen dioxide] - GUAJA [guajacol (modif. Jakobs-Hochheiser) - spectrophotometry] µg/m³ Yes No 0 N N N N N N 1d 2003-01-01 2012-10-31
L2 D2 5 NOₓ [nitrogen oxides] - GUAJA [guajacol (modif. Jakobs-Hochheiser) - spectrophotometry] µg/m³ No No 0 N N N N N N 1d 1991-10-01 1996-12-31
L2 D2 5 NOₓ [nitrogen oxides] - GUAJA [guajacol (modif. Jakobs-Hochheiser) - spectrophotometry] µg/m³ No No 0 N N N N N N 1d 1998-01-01 2002-12-31
L2 D2 6 SPM [suspended particulate matter] - GRV [gravimetry] µg/m³ No No 1 N N N N N N 1d 1977-01-01 1991-12-31
L2 D2 1 SPM [suspended particulate matter] - GRV [gravimetry] µg/m³ No No 0 N N N N N N 1d 1971-10-01 2003-05-31
L2 D2 2 SO₄²⁻ [sulphate - particles] - HPLC [high pressure liquid chromatography] µg/m³ No No 0 N N N N N N 1d 1994-01-01 1995-12-31
L2 D2 0 NO₃⁻ [nitrate ions] - IC [ion chromatography] µg/m³ No No 0 N N N N N N 1d 1994-01-01 1995-12-31
List of laboratories
Laboratory number 1 Laboratoř OČO, pob. Brno
Kroftova 43
61667 Brno
Tel.: 541421059/43
 
E-mail: hana.smekalova@chmi.cz
Laboratory number 2 ČHMÚ - pob.Ostrava
K Myslivně 3/2182
70800 Ostrava-Poruba
Tel.: 596900263
 
E-mail: ooco_ova@chmi.cz
List of data suppliers
Supplier number 1 ČHMÚ - pob.Brno
Kroftova 43
61667 Brno
Tel.: 541421043
 
E-mail: hana.smekalova@chmi.cz
Supplier number 2 Laboratory of CHMI

Tel.:
 
E-mail:
Supplier number 3 ČHMÚ - pob.Ostrava
K Myslivně 3/2182
70800 Ostrava-Poruba
Tel.: 596 900 239
 
E-mail: daniel.hladky@chmi.cz