Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-04-23 04:52 CEST


Basic data
Code: SSTE0
Old ISKO number: 1745
Locality: Stehelceves
Type of measuring programme: Heavy metal in PM10
Measuring networks:
Administrator
ZÚ se sídlem v Ústí n.Labem
Pasteurova 9
400 01 Ústí n/L
Tel.: 724 034 029
 
E-mail: pavel.knedlik@zuusti.cz
Target of the measuring programme
Evaluation of the significant sources effect on air pollution level
Cover
measuring box (heated)
Note
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 0 Cr [chromium] LVSauto1 [LVS - automatic filter change 1,0 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 Y N A A R A 14d 2023-01-01
L1 D1 0 Mn [manganese] LVSauto1 [LVS - automatic filter change 1,0 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 Y N A A R A 14d 2023-01-01
L1 D1 0 Ni [nickel] LVSauto1 [LVS - automatic filter change 1,0 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 Y N A A R A 14d 2023-01-01
L1 D1 0 As [arsenic] LVSauto1 [LVS - automatic filter change 1,0 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 Y N A A R A 14d 2023-01-01
L1 D1 0 Cd [cadmium] LVSauto1 [LVS - automatic filter change 1,0 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 Y N A A R A 14d 2023-01-01
L1 D1 0 Pb [lead] LVSauto1 [LVS - automatic filter change 1,0 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m³ Yes No 0 Y N A A R A 14d 2023-01-01
L1 D1 0 Cr [chromium] - AAS [atomic absorption spectrometry] ng/m³ No No 0 Y N N N N N 14d 2006-01-02 2013-12-31
L1 D1 0 Cr [chromium] LVSauto1 [LVS - automatic filter change 1,0 m3/h] ICP-OES [inductively coupled plasma - optical emission spectrometry] ng/m³ Yes No 0 Y N A A R A 14d 2014-01-01 2022-12-31
L1 D1 0 Mn [manganese] - AAS [atomic absorption spectrometry] ng/m³ No No 0 Y N N N N N 14d 2006-01-02 2013-12-31
L1 D1 0 Mn [manganese] LVSauto1 [LVS - automatic filter change 1,0 m3/h] ICP-OES [inductively coupled plasma - optical emission spectrometry] ng/m³ Yes No 0 Y N A A R A 14d 2014-01-01 2022-12-31
L1 D1 0 Ni [nickel] - AAS [atomic absorption spectrometry] ng/m³ No No 0 Y N N N N N 14d 2006-01-02 2013-12-31
L1 D1 0 Ni [nickel] LVSauto1 [LVS - automatic filter change 1,0 m3/h] ICP-OES [inductively coupled plasma - optical emission spectrometry] ng/m³ Yes No 0 Y N A A R A 14d 2014-01-01 2022-12-31
L1 D1 0 As [arsenic] - AAS [atomic absorption spectrometry] ng/m³ No No 0 Y N N N N N 14d 2006-01-02 2013-12-31
L1 D1 0 As [arsenic] LVSauto1 [LVS - automatic filter change 1,0 m3/h] ICP-OES [inductively coupled plasma - optical emission spectrometry] ng/m³ Yes No 0 Y N A A R A 14d 2014-01-01 2022-12-31
L1 D1 0 Cd [cadmium] - AAS [atomic absorption spectrometry] ng/m³ No No 0 Y N N N N N 14d 2006-01-02 2013-12-31
L1 D1 0 Cd [cadmium] LVSauto1 [LVS - automatic filter change 1,0 m3/h] ICP-OES [inductively coupled plasma - optical emission spectrometry] ng/m³ Yes No 0 Y N A A R A 14d 2014-01-01 2022-12-31
L1 D1 0 Pb [lead] - AAS [atomic absorption spectrometry] ng/m³ No No 0 Y N N N N N 14d 2006-01-02 2013-12-31
L1 D1 0 Pb [lead] LVSauto1 [LVS - automatic filter change 1,0 m3/h] ICP-OES [inductively coupled plasma - optical emission spectrometry] ng/m³ Yes No 0 Y N A A R A 14d 2014-01-01 2022-12-31
List of laboratories
Laboratory number 1 ZU se sidlem v Usti n. L.
Fr. Kloze 2316
272 01 Kladno
Tel.: 312 292 174
 
E-mail: alena.svobodova@zuusti.cz
List of data suppliers
Supplier number 1 ZU se sidlem v Usti n. L.
Pasteurova 9
400 01 Ústí n. Labem
Tel.: 724 034 029
 
E-mail: pavel.knedlik@zuusti.cz