Information about air quality in the Czech Republic
Measuring programme table
Updated: 2013-04-03 02:42 CEST
| Basic data | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Code: | AVELA | |||||||||||
| Old ISKO number: | 777 | |||||||||||
| Locality: | Pha6-Veleslavin | |||||||||||
| Type of measuring programme: | Automated measuring program | |||||||||||
| Measuring networks: | EUROAIRNET, National air pollution network | |||||||||||
| Administrator | ||||||||||||
| ČHMÚ - Libuš CLI Gen.Šišky 942 14200 Praha 4 - Libuš |
Tel.: 244033467 | |||||||||||
| Fax:.: 241727935 | ||||||||||||
| E-mail: silhavy@chmi.cz | ||||||||||||
| Target of the measuring programme | ||||||||||||
| Cover | ||||||||||||
| container (air-conditioned) | ||||||||||||
| Note | ||||||||||||
| Stanice je umístěna v parku asi 50m od hlavní komunikace. 30.11.2000 došlo k výměně prachoměru. Verewa F703V a sondy PM10 Kalman byly nahrazeny prachoměrem FH 62 I-R se sondami PM10 Anderson. 1.6.2004 došlo k výměně prachoměru FH62 I-R se sondou PM10 Anderson za prac homěr MP101M se sondou PM10 Digitel. | ||||||||||||
| Measurements | ||||||||||||
| Lab. | Supp. | Instr. | Component | Method | Unit | A | R | Par. | Ac | Interval | Date of start | Date of end |
| 1 | 1 | 17 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | Yes | 1h | 2004-01-01 | 2008-07-31 |
| 1 | 1 | 17 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | No | 30min | 1992-04-01 | 2003-12-31 |
| 1 | 1 | 17 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | Yes | 10min | 2004-10-01 | 2008-07-31 |
| 1 | 1 | 18 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | Yes | 1h | 2004-01-01 | 2011-12-31 |
| 1 | 1 | 18 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 1992-02-01 | 2003-12-31 |
| 1 | 1 | 18 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | Yes | 1h | 2004-01-01 | 2011-12-31 |
| 1 | 1 | 18 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 1992-04-01 | 2003-12-31 |
| 1 | 1 | 18 | NOx [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | Yes | 1h | 2004-01-01 | 2011-12-31 |
| 1 | 1 | 18 | NOx [nitrogen oxides] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | No | 30min | 1992-04-01 | 2003-12-31 |
| 1 | 1 | 22 | O3 [ozone] | UVABS [UV-absorption] | µg/m3 | Yes | No | 0 | Yes | 1h | 2004-01-01 | 2011-12-31 |
| 1 | 1 | 22 | O3 [ozone] | UVABS [UV-absorption] | µg/m3 | Yes | No | 0 | No | 30min | 1996-07-01 | 2003-12-31 |
| 1 | 1 | 25 | PM10 [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | Yes | 1h | 2004-01-01 | 2011-12-31 |
| 1 | 1 | 25 | PM10 [particles PM10] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | No | 30min | 1995-10-01 | 2003-12-31 |
| 1 | 1 | 24 | SPM [suspended particulate matter] | RADIO [radiometry - beta ray absorption] | µg/m3 | No | No | 0 | No | 30min | 1992-04-01 | 1995-10-31 |
| 1 | 1 | 0 | p [atmospheric pressure] | APRESS [atmospheric pressure measurement] | hPa | No | No | 0 | No | 30min | 1992-04-01 | 1999-08-31 |
| 1 | 1 | 0 | T [temperature (unspecificated)] | PT100 [resistance method] | K | No | No | 0 | No | 30min | 1996-01-01 | 1999-08-31 |
| List of laboratories | ||||||||||||
| Laboratory number1 | ČHMÚ-CLI TK Gen.Šišky 942 14300 Praha 4 - Libuš |
Tel.: 244033451 | ||||||||||
| Fax:.: 241727935 | ||||||||||||
| E-mail: novakj@chmi.cz | ||||||||||||
| List of data suppliers | ||||||||||||
| Supplier number1 | ČHMÚ - Libuš AIM Generála Šišky 942 14000 Praha 4 - Libuš |
Tel.: 244033467 | ||||||||||
| Fax:.: 241727935 | ||||||||||||
| E-mail: silhavy@chmi.cz | ||||||||||||
ISKO