Information about air quality in the Czech Republic

Measuring programme table

Updated: 2024-04-23 04:52 CEST


Basic data
Code: AREPA
Old ISKO number: 771
Locality: Praha 1-n. Republiky
Type of measuring programme: Automated measuring program
Measuring networks: National air pollution monitoring network , EUROAIRNET
Administrator
ČHMÚ - Libuš CLI
Gen.Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033451
 
E-mail: stepan.rychlik@chmi.cz
Target of the measuring programme
Usage for operational management and regulation (SRVS)
Cover
container (air-conditioned)
Note
Measurements
Lab. Supp. Instr. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
L1 D1 94 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 Y A A A R A 1h 2007-06-26
L1 D1 94 NO₂ [nitrogen dioxide] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 Y A A A R A 1h 2007-06-26
L1 D1 94 NOₓ [nitrogen oxides] - CHLM [chemiluminescence] µg/m³ Yes Yes 0 Y A A A R A 1h 2007-06-26
L1 D1 25 PM₁₀ [particles PM10] - RADIO [radiometry - beta ray absorption] µg/m³ Yes Yes 0 Y N A A A A 1h 2007-07-25
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg/m³ Yes No 0 Y N N N N N 1h 2007-06-26 2008-07-31
L1 D1 17 SO₂ [sulphur dioxide] - UVFL [UV-fluorescence] µg/m³ Yes No 0 Y N N N N N 10min 2007-06-26 2008-07-31
L1 D1 20 CO [carbon monoxide] - IRABS [IR corel. absorption spectrometry] µg/m³ Yes No 0 Y N N N N N 1h 2007-07-01 2009-05-31
L1 D1 18 O₃ [ozone] - UVABS [UV-absorption] µg/m³ Yes Yes 0 Y N N N N N 1h 2007-06-26 2011-05-31
L1 D1 30 BZN [Benzene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes Yes 0 Y N N N N N 1h 2007-07-17 2012-03-31
L1 D1 30 TLN [toluene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes Yes 0 Y N N N N N 1h 2007-06-26 2012-03-31
L1 D1 30 EBZN [ethylbenzene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes No 0 Y N N N N N 1h 2007-08-01 2009-12-31
L1 D1 30 MPXY [m,p-xylene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes No 0 Y N N N N N 1h 2007-08-01 2009-12-31
L1 D1 30 OXY [o-xylene] - GC-PID [gas chromatography - photo-ionization detection] µg/m³ Yes No 0 Y N N N N N 1h 2007-10-01 2009-12-31
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] m/s No Yes 0 N N N N N N 1h 2007-06-26 2012-12-31
L1 D1 35 WV [wind velocity] - U-SONIC [ultrasonic anemometer] m/s No Yes 0 N N N N N N 10min 2007-06-26 2012-12-31
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] deg No Yes 0 N N N N N N 1h 2007-06-26 2012-12-31
L1 D1 35 WD [wind direction] - U-SONIC [ultrasonic anemometer] deg No Yes 0 N N N N N N 10min 2007-06-26 2012-12-31
L1 D1 35 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] m/s No Yes 0 N N N N N N 1h 2007-06-26 2012-12-31
L1 D1 35 WVm [short-term wind velocity maximum] - OPEL [optoelectronic method] m/s No Yes 0 N N N N N N 10min 2007-06-26 2012-12-31
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] deg No Yes 0 N N N N N N 1h 2007-06-26 2012-12-31
L1 D1 35 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] deg No Yes 0 N N N N N N 10min 2007-06-26 2012-12-31
L1 D1 41 h [relative air humidity (h. of air)] - CAP [capacitance sensor] % No Yes 0 N N N N N N 1h 2007-06-26 2012-12-31
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] W/m 2 No Yes 0 N N N N N N 1h 2007-07-12 2012-12-31
L1 D1 43 GLRD [global radiation] - TDM [temperature difference method] W/m 2 No Yes 0 N N N N N N 10min 2007-07-16 2012-12-31
L1 D1 41 T2m [temperature 2m above terrain] - PT100 [resistance method] K No Yes 0 N N N N N N 1h 2007-06-26 2012-12-31
List of laboratories
Laboratory number 1 ČHMÚ-CLI TK
Gen.Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033451
 
E-mail: stepan.rychlik@chmi.cz
List of data suppliers
Supplier number 1 ČHMÚ - Libuš AIM
Generála Šišky 942
143 00 Praha 4 - Kamýk
Tel.: 244033467
 
E-mail: jan.silhavy@chmi.cz