Information about air quality in the Czech Republic

Measuring programme table

Updated: 2017-04-10 14:16 CEST


Basic data
Code: UULMA
Old ISKO number: 1571
Locality: Usti n.L.-mesto
Type of measuring programme: Automated measuring program
Measuring networks: EUROAIRNET, National air pollution monitoring network
Administrator
ČHMÚ-pobočka Ústí n/Labem
Pošt. přihrádka 2
40011 Ústí n/Labem
Tel.: 472706053
Fax:.: 472706024
E-mail: bitter@chmi.cz
Target of the measuring programme
Evalution of concentration in urban areas, Usage for operational management and regulation (SRVS), Evaluation of the effect on other environment components, damage evaluation
Cover
container (air-conditioned)
Note
Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní.
Measurements
Lab. Supp. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
1 1 SO2 [sulphur dioxide] - UVFL [UV-fluorescence] µg/m3 Yes Yes 0 N N A N R N 1h 2005-01-01
1 1 SO2 [sulphur dioxide] - UVFL [UV-fluorescence] µg/m3 Yes Yes 0 N N A N R N 10min 2005-01-01
1 1 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m3 Yes Yes 0 A A A N R N 1h 2005-01-01
1 1 NO2 [nitrogen dioxide] - CHLM [chemiluminescence] µg/m3 Yes Yes 0 A A A N R N 1h 2005-01-01
1 1 NOx [nitrogen oxides] - CHLM [chemiluminescence] µg/m3 Yes Yes 0 A A A N R N 1h 2005-01-01
1 1 O3 [ozone] - UVABS [UV-absorption] µg/m3 Yes Yes 0 N N A N R N 1h 2005-01-01
1 1 PM10 [particles PM10] - RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 A N A A R A 1h 2005-01-01
1 1 GLRD [global radiation] - TDM [temperature difference method] W/m2 Yes Yes 0 N N A N N N 1h 2005-01-01
1 1 GLRD [global radiation] - TDM [temperature difference method] W/m2 Yes Yes 0 N N A N N N 10min 2005-01-01
1 1 CO [carbon monoxide] - IRABS [IR corel. absorption spectrometry] µg/m3 Yes Yes 0 A N N N N N 1h 2005-01-01 2012-12-31
1 1 Hg0 [gaseous mercury] - AFS [low-temperature gas atomic fluorescence spectrometry] ng/m3 No Yes 0 N N N N N N 1h 2005-01-01 2011-01-10
1 1 BZN [Benzene] - GC-PID [gas chromatography - photo-ionization detection] µg/m3 Yes Yes 0 A N N N N N 1h 2005-01-01 2015-04-30
1 1 TLN [toluene] - GC-PID [gas chromatography - photo-ionization detection] µg/m3 Yes Yes 0 A N N N N N 1h 2005-01-01 2015-04-30
1 1 EBZN [ethylbenzene] - GC-PID [gas chromatography - photo-ionization detection] µg/m3 Yes No 0 A N N N N N 1h 2005-01-01 2009-12-31
1 1 MPXY [m,p-xylene] - GC-PID [gas chromatography - photo-ionization detection] µg/m3 Yes No 0 A N N N N N 1h 2005-01-01 2009-12-31
1 1 OXY [o-xylene] - GC-PID [gas chromatography - photo-ionization detection] µg/m3 Yes No 0 A N N N N N 1h 2005-01-01 2009-12-31
List of laboratories
Laboratory number 1 CHMI-Usti n/L AIM
pošt. přihrádka 2
400 11 Ústí nad Labem
Tel.: 472 706 053
Fax:.: 472 706 024
E-mail: bitter@chmi.cz
List of data suppliers
Supplier number 1 ČHMÚ-pobočka Ústí n/Labem-AIM
Pošt. přihrádka 2
40011 Ústí n/Labem
Tel.: 472706053
Fax:.: 472706024