Information about air quality in the Czech Republic

Measuring programme table

Updated: 2017-04-10 14:16 CEST


Basic data
Code: TOVKA
Old ISKO number: 1186
Locality: Opava-Katerinky
Type of measuring programme: Automated measuring program
Measuring networks: IRIS, EUROAIRNET, National air pollution monitoring network
Administrator
ČHMÚ - pob.Ostrava
K Myslivně 3/2182
70800 Ostrava - Poruba
Tel.: 596 900 218
Fax:.:
E-mail: krejci@chmi.cz
Target of the measuring programme
Evalution of concentration in urban areas, Usage for operational management and regulation (SRVS)
Cover
container (air-conditioned)
Note
Dobrá lokalita na sídlišti. Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření.
Measurements
Lab. Supp. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
1 1 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m3 Yes Yes 0 A A A N R N 1h 2004-01-01
1 1 NO2 [nitrogen dioxide] - CHLM [chemiluminescence] µg/m3 Yes Yes 0 A A A N R N 1h 2004-01-01
1 1 NOx [nitrogen oxides] - CHLM [chemiluminescence] µg/m3 Yes Yes 0 A A A N R N 1h 2004-01-01
1 1 O3 [ozone] - UVABS [UV-absorption] µg/m3 Yes Yes 0 A N A N R N 1h 2011-01-01
1 1 PM2,5 [fine particles PM2.5] - RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 A N A N N A 1h 2015-06-15
1 1 PM10 [particles PM10] - RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 A N A A A A 1h 2004-01-01
1 1 h [relative air humidity (h. of air)] - CAP [capacitance sensor] % Yes Yes 0 N N A N N N 1h 2004-11-18
1 1 GLRD [global radiation] - TDM [temperature difference method] W/m2 Yes Yes 0 N N A N N N 1h 2011-03-07
1 1 GLRD [global radiation] - TDM [temperature difference method] W/m2 Yes Yes 0 N N A N N N 10min 2015-01-01
1 1 T2m [temperature 2m above terrain] - PT100 [resistance method] K Yes Yes 0 N N A N N N 1h 2004-11-18
1 1 SO2 [sulphur dioxide] - UVFL [UV-fluorescence] µg/m3 Yes Yes 0 A N N N N N 1h 2004-01-01 2012-12-31
1 1 SO2 [sulphur dioxide] - UVFL [UV-fluorescence] µg/m3 Yes No 0 N N N N N N 30min 1994-01-25 2003-12-31
1 1 SO2 [sulphur dioxide] - UVFL [UV-fluorescence] µg/m3 Yes Yes 0 A N N N N N 10min 2004-01-01 2012-12-31
1 1 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m3 Yes No 0 N N N N N N 30min 1994-01-25 2003-12-31
1 1 NO2 [nitrogen dioxide] - CHLM [chemiluminescence] µg/m3 Yes No 0 N N N N N N 30min 1994-01-25 2003-12-31
1 1 NOx [nitrogen oxides] - CHLM [chemiluminescence] µg/m3 Yes No 0 N N N N N N 30min 1994-01-25 2003-12-31
1 1 CO [carbon monoxide] - IRABS [IR corel. absorption spectrometry] µg/m3 No No 0 N N N N N N 30min 1995-10-26 2002-12-31
1 1 PM10 [particles PM10] - RADIO [radiometry - beta ray absorption] µg/m3 Yes No 0 N N N N N N 30min 1995-10-21 2003-12-31
1 1 SPM [suspended particulate matter] - RADIO [radiometry - beta ray absorption] µg/m3 No No 0 N N N N N N 30min 1994-01-25 1995-10-20
1 1 RAD_A [RAD_A] - RAD [dosimeter] uSv/hod No Yes 0 N N N N N N 1h 2004-01-01 2017-03-14
1 1 RAD_A [RAD_A] - RAD [dosimeter] uSv/hod No Yes 0 N N N N N N 10min 2004-01-01 2017-03-14
1 1 RAD_B [RAD_B] - RAD [dosimeter] uSv/hod No Yes 0 N N N N N N 1h 2004-01-01 2017-03-14
1 1 RAD_B [RAD_B] - RAD [dosimeter] uSv/hod No Yes 0 N N N N N N 10min 2004-01-01 2017-03-14
1 1 RAD_C [RAD_C] - RAD [dosimeter] uSV/hod No Yes 0 N N N N N N 1h 2004-01-01 2017-03-14
1 1 RAD_C [RAD_C] - RAD [dosimeter] uSV/hod No Yes 0 N N N N N N 10min 2004-01-08 2017-03-14
1 1 WV [wind velocity] - U-SONIC [ultrasonic anemometer] m/s No Yes 0 N N N N N N 1h 2004-11-18 2015-06-08
1 1 WV [wind velocity] - U-SONIC [ultrasonic anemometer] m/s No No 0 N N N N N N 10min 2004-11-18 2015-06-08
1 1 WD [wind direction] - U-SONIC [ultrasonic anemometer] deg No Yes 0 N N N N N N 1h 2004-11-18 2015-06-08
1 1 WD [wind direction] - U-SONIC [ultrasonic anemometer] deg No Yes 0 N N N N N N 10min 2004-11-18 2015-06-08
1 1 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] m/s No Yes 0 N N N N N N 1h 2007-01-01 2015-06-08
1 1 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] m/s No Yes 0 N N N N N N 10min 2008-01-01 2015-06-08
1 1 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] deg No Yes 0 N N N N N N 1h 2007-01-01 2015-06-08
1 1 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] deg No Yes 0 N N N N N N 10min 2008-01-01 2015-06-08
List of laboratories
Laboratory number 1 CHMI-brand Ostrava AIM
K Myslivně 3/2182
708 00 Ostrava - Poruba
Tel.: 596 900 228
Fax:.: 596 910 284
E-mail: ooco_ova@chmi.cz
List of data suppliers
Supplier number 1 CHMI-brand Ostrava AIM
K Myslivně 3/2182
708 00 Ostrava-Poruba
Tel.: 596 900 239
Fax:.: 596 910 284
E-mail: ooco_ova@chmi.cz