Information about air quality in the Czech Republic

Measuring programme table

Updated: 2017-03-02 17:35 CET


Basic data
Code: UULK0
Old ISKO number: 1413
Locality: Usti n.L.-Kockov
Type of measuring programme: Heavy metal in PM10
Measuring networks: National air pollution monitoring network
Administrator
ČHMÚ-pob. Ústí n. Labem
Pošt.přihrádka 2
40011 Ústí nad Labem
Tel.: 472706057
Fax:.: 472706024
E-mail: placha@chmi.cz
Target of the measuring programme
Evalution of total level of concentrations beckground
Cover
sampler (situated separately)
Note
Jihovýchodní svah nad budovou pobočky (v meteorologické zahrádce), otevřený do podkrušnohorské kotliny s převládajícími severozápadními větry. Odběr : 24hod, analýza kovů každý 5.den.
Measurements
Lab. Supp. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
1 1 PM10 [particles PM10] LVSman2.3 [LVS - manual filter change 2,3 m3/h] GRV [gravimetry] µg/m3 Yes No 0 A A A A R A 1d/2d 2005-01-01
1 2 V [vanadium] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 N A A A R A 1d/2d 2011-01-01
1 2 Cr [chromium] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 N A A A R A 1d/2d 2011-01-01
1 2 Mn [manganese] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 N A A A R A 1d/2d 2005-01-01
1 2 Fe [iron] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 N N A A R A 1d/2d 2011-01-01
1 2 Co [cobalt] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 N N A A R A 1d/2d 2011-01-01
1 2 Ni [nickel] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 A A A A R A 1d/2d 2005-01-01
1 2 Cu [copper] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 N A A A R A 1d/2d 2005-01-01
1 2 Zn [zinc] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 N A A A R A 1d/2d 2011-01-01
1 2 As [arsenic] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 A A A A R A 1d/2d 2005-01-01
1 2 Se [selenium] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 N N A A R A 1d/2d 2011-01-01
1 2 Cd [cadmium] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 A A A A R A 1d/2d 2005-01-01
1 2 Pb [lead] LVSman2.3 [LVS - manual filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 A A A A R A 1d/2d 2005-01-01
1 2 PM10 [particles PM10] - GRV [gravimetry] µg/m3 No No 0 N N N N N N 1d/5d 1996-01-05 2004-12-31
1 2 V [vanadium] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 N N N N N N 1d/5d 1996-01-05 2003-12-30
1 2 Cr [chromium] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 N N N N N N 1d/5d 1996-01-05 2004-12-31
1 2 Mn [manganese] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 N N N N N N 1d/5d 1996-01-05 2004-12-31
1 2 Fe [iron] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 N N N N N N 1d/5d 1996-01-05 2004-12-31
1 2 Ni [nickel] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 N N N N N N 1d/5d 1996-01-05 2004-12-31
1 2 Cu [copper] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 N N N N N N 1d/5d 1996-01-05 2004-12-31
1 2 As [arsenic] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 N N N N N N 1d/5d 1996-01-05 2004-12-31
1 2 Se [selenium] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 N N N N N N 1d/5d 1996-01-05 2004-12-31
1 2 Cd [cadmium] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 N N N N N N 1d/5d 1996-01-05 2004-12-31
1 2 Sb [antimony] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 N N N N N N 1d/5d 1996-01-05 2004-12-31
1 2 Pb [lead] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 N N N N N N 1d/5d 1996-01-05 2004-12-31
1 2 Pb208/206 [isotopic ratio 208 Pb/206 Pb] - ICP-MS [inductively coupled plasma - mass spectrometry] number No No 0 N N N N N N 1d/5d 1996-01-05 2003-12-30
1 2 Pb207/206 [isotopic ratio 207 Pb/206Pb] - ICP-MS [inductively coupled plasma - mass spectrometry] number No No 0 N N N N N N 1d/5d 1996-01-05 2003-12-30
List of laboratories
Laboratory number 1 ČHMÚ-CLI TK
Gen.Šišky 942
143 00 Praha 4 - Libuš
Tel.: 244033451
Fax:.:
E-mail: novakj@chmi.cz
List of data suppliers
Supplier number 1 CHMI-CLI TK
Generála Šišky 942
143 00 Praha 4 - Libuš
Tel.: 244 033 484
Fax:.:
E-mail: lucie.sedlakova@chmi.cz
Supplier number 2 ČHMÚ-CLI TK
Generála Šišky 942
14300 Praha 4 - Libuš
Tel.: 244033482
Fax:.:
E-mail: rychliks@chmi.cz