Information about air quality in the Czech Republic

Measuring programme table

Updated: 2017-03-02 17:35 CET


Basic data
Code: TOROK
Old ISKO number: 1940
Locality: Ostrava-Radvanice OZO
Type of measuring programme: Combination measuring program
Measuring networks:
Administrator
ZU-Ostrava
Partyzánské nám. 7
702 00 Ostrava 1
Tel.: 596 200 361
Fax:.: 596 118 661
E-mail: hyglab.ov@zuova.cz
Target of the measuring programme
Evalution of concentration in urban areas
Cover
container (air-conditioned)
Note
Measurements
Lab. Supp. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
1 1 SO2 [sulphur dioxide] - UVFL [UV-fluorescence] µg/m3 Yes Yes 0 A N A A N A 1h 2013-01-01
1 1 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m3 Yes Yes 0 A N A A N A 1h 2013-01-01
1 1 NO2 [nitrogen dioxide] - CHLM [chemiluminescence] µg/m3 Yes Yes 0 A N A A N A 1h 2013-01-01
1 1 NOx [nitrogen oxides] - CHLM [chemiluminescence] µg/m3 Yes Yes 0 A N A A N A 1h 2013-01-01
1 1 O3 [ozone] - UVABS [UV-absorption] µg/m3 Yes Yes 0 A N A A N A 1h 2013-01-01
1 1 PM10 [particles PM10] - RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 A N A A N A 1h 2013-01-01
1 1 WV [wind velocity] - OPEL [optoelectronic method] m/s No Yes 0 N N N N N N 1h 2013-01-01
1 1 WD [wind direction] - OPEL [optoelectronic method] deg No Yes 0 N N N N N N 1h 2013-01-01
1 1 h [relative air humidity (h. of air)] - HAIR [hair hygrometer] % No Yes 0 N N N N N N 1h 2013-01-01
1 1 T2m [temperature 2m above terrain] - PT100 [resistance method] K No Yes 0 N N N N N N 1h 2013-01-01
List of laboratories
Laboratory number 1 KHS-Ostrava
Partyzánské náměstí 7
70200 Ostrava 1
Tel.: 596 200 361
Fax:.: 596 118 661
E-mail: hyglab.ov@zuova.cz
List of data suppliers
Supplier number 1 KHS-Ostrava
Partyzánské nám. 7
70200 Ostrava 1
Tel.: 596 200 375
Fax:.: 596 118 661
E-mail: hana.miturova@zuova.cz