Information about air quality in the Czech Republic

Measuring programme table

Updated: 2017-03-02 17:35 CET


Basic data
Code: LFRUA
Old ISKO number: 1018
Locality: Frydlant-Udoli
Type of measuring programme: Automated measuring program
Measuring networks: National air pollution monitoring network
Administrator
ČHMÚ-pobočka Ústí n/Labem
Pošt. přihrádka 2
40011 Ústí n/Labem
Tel.: 472706053
Fax:.: 472706024
E-mail: bitter@chmi.cz
Target of the measuring programme
Evaluation of the significant sources effect on air pollution level, Usage for operational management and regulation (SRVS)
Cover
container (air-conditioned)
Note
Mírný severní svah ve volné přírodě od Frýdlantu ( za kopcem). Měření meteorologických veličin je pouze doprovodné a nenahrazuje standardní meteorologická měření. GLRD-čidla jsou čištěna pouze při údržbě stanice a hodnoty jsou zejména v zimním období pouze indikativní.
Measurements
Lab. Supp. Component Sampling method Measuring method Unit A R Par. Acc. ICT Met. tr. Valid. Tests ek. Uncert. Interval Date of start Date of end
1 1 SO2 [sulphur dioxide] - UVFL [UV-fluorescence] µg/m3 Yes Yes 0 N N N N N N 1h 2004-01-01 2015-07-08
1 1 SO2 [sulphur dioxide] - UVFL [UV-fluorescence] µg/m3 Yes No 0 N N N N N N 30min 1992-12-09 2003-12-31
1 1 SO2 [sulphur dioxide] - UVFL [UV-fluorescence] µg/m3 Yes Yes 0 N N N N N N 10min 2004-10-01 2015-07-08
1 1 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m3 Yes Yes 0 N N N N N N 1h 2004-01-01 2012-12-31
1 1 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m3 Yes No 0 N N N N N N 30min 1992-12-09 2003-12-31
1 1 NO2 [nitrogen dioxide] - CHLM [chemiluminescence] µg/m3 Yes Yes 0 N N N N N N 1h 2004-01-01 2012-12-31
1 1 NO2 [nitrogen dioxide] - CHLM [chemiluminescence] µg/m3 Yes No 0 N N N N N N 30min 1992-12-09 2003-12-31
1 1 NOx [nitrogen oxides] - CHLM [chemiluminescence] µg/m3 Yes Yes 0 N N N N N N 1h 2004-01-01 2012-12-31
1 1 NOx [nitrogen oxides] - CHLM [chemiluminescence] µg/m3 Yes No 0 N N N N N N 30min 1992-12-09 2003-12-31
1 1 O3 [ozone] - UVABS [UV-absorption] µg/m3 Yes Yes 0 A N N N N N 1h 2010-12-23 2015-07-08
1 1 PM10 [particles PM10] - RADIO [radiometry - beta ray absorption] µg/m3 Yes No 0 A N N N N N 1h 2004-01-01 2009-09-02
1 1 PM10 [particles PM10] - RADIO [radiometry - beta ray absorption] µg/m3 Yes No 0 N N N N N N 30min 1995-10-20 2003-12-31
1 1 SPM [suspended particulate matter] - RADIO [radiometry - beta ray absorption] µg/m3 No No 0 N N N N N N 30min 1992-12-09 1995-10-19
1 1 WV [wind velocity] - OPEL [optoelectronic method] m/s No No 0 N N N N N N 1h 2004-01-01 2006-01-31
1 1 WV [wind velocity] - U-SONIC [ultrasonic anemometer] m/s No Yes 0 N N N N N N 1h 2006-02-01 2015-07-08
1 1 WV [wind velocity] - OPEL [optoelectronic method] m/s No No 0 N N N N N N 30min 1995-10-28 2003-12-31
1 1 WV [wind velocity] - OPEL [optoelectronic method] m/s No No 0 N N N N N N 10min 2004-01-01 2006-01-31
1 1 WV [wind velocity] - U-SONIC [ultrasonic anemometer] m/s No Yes 0 N N N N N N 10min 2006-02-01 2015-07-08
1 1 WD [wind direction] - OPEL [optoelectronic method] deg No No 0 N N N N N N 1h 2004-01-01 2006-01-31
1 1 WD [wind direction] - U-SONIC [ultrasonic anemometer] deg No Yes 0 N N N N N N 1h 2006-02-01 2015-07-08
1 1 WD [wind direction] - OPEL [optoelectronic method] deg No No 0 N N N N N N 30min 1995-10-28 2003-12-31
1 1 WD [wind direction] - OPEL [optoelectronic method] deg No No 0 N N N N N N 10min 2004-01-01 2006-01-31
1 1 WD [wind direction] - U-SONIC [ultrasonic anemometer] deg No Yes 0 N N N N N N 10min 2006-02-01 2015-07-08
1 1 WVm [short-term wind velocity maximum] - OPEL [optoelectronic method] m/s No No 0 N N N N N N 1h 2004-01-01 2006-01-31
1 1 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] m/s No Yes 0 N N N N N N 1h 2007-01-01 2015-07-08
1 1 WVm [short-term wind velocity maximum] - OPEL [optoelectronic method] m/s No No 0 N N N N N N 10min 2004-01-01 2006-01-31
1 1 WVm [short-term wind velocity maximum] - U-SONIC [ultrasonic anemometer] m/s No Yes 0 N N N N N N 10min 2007-01-01 2015-07-08
1 1 WDm [short-term wind direction maximum] - OPEL [optoelectronic method] deg No No 0 N N N N N N 1h 2004-01-01 2006-01-31
1 1 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] deg No Yes 0 N N N N N N 1h 2007-01-01 2015-07-08
1 1 WDm [short-term wind direction maximum] - OPEL [optoelectronic method] deg No No 0 N N N N N N 10min 2004-01-01 2006-01-31
1 1 WDm [short-term wind direction maximum] - U-SONIC [ultrasonic anemometer] deg No Yes 0 N N N N N N 10min 2007-01-01 2015-07-08
1 1 p [atmospheric pressure] - APRESS [atmospheric pressure measurement] hPa No No 0 N N N N N N 1h 2004-01-01 2009-12-31
1 1 p [atmospheric pressure] - APRESS [atmospheric pressure measurement] hPa No No 0 N N N N N N 30min 1995-10-28 2003-12-31
1 1 h [relative air humidity (h. of air)] - CAP [capacitance sensor] % No Yes 0 N N N N N N 1h 2004-01-01 2015-07-08
1 1 h [relative air humidity (h. of air)] - CAP [capacitance sensor] % No No 0 N N N N N N 30min 1997-07-01 2003-12-31
1 1 GLRD [global radiation] - TDM [temperature difference method] W/m2 No Yes 0 N N N N N N 1h 2004-01-01 2015-07-08
1 1 GLRD [global radiation] - TDM [temperature difference method] W/m2 No No 0 N N N N N N 30min 1995-10-28 2003-12-31
1 1 GLRD [global radiation] - TDM [temperature difference method] W/m2 No Yes 0 N N N N N N 10min 2004-10-01 2015-07-08
1 1 T2m [temperature 2m above terrain] - PT100 [resistance method] K No Yes 0 N N N N N N 1h 2004-01-01 2015-07-08
1 1 T2m [temperature 2m above terrain] - PT100 [resistance method] K No No 0 N N N N N N 30min 1997-07-01 2003-12-31
List of laboratories
Laboratory number 1
pošt. přihrádka 2
400 11 Ústí nad Labem
Tel.: 472 706 053
Fax:.: 472 706 024
E-mail: bitter@chmi.cz
List of data suppliers
Supplier number 1 ČHMÚ-pobočka Ústí n/Labem-AIM
Pošt. přihrádka 2
40011 Ústí n/Labem
Tel.: 472706053
Fax:.: 472706024