Information about air quality in the Czech Republic

Measuring programme table

Updated: 2015-05-25 16:23 CEST


Basic data
Code: SVELA
Old ISKO number: 792
Locality: Veltrusy
Type of measuring programme: Automated measuring program
Measuring networks:
Administrator
Kaučuk a.s. Kralupy nad Vltavou
Wichterleho 809
27852 Kralupy nad Vltavou
Tel.: 315 718 290
Fax:.: 315 713 809
E-mail: petr.kolator@crc.cz
Target of the measuring programme
Usage for operational management and regulation (SRVS)
Cover
container (air-conditioned)
Note
Jižní okraj obce.
Measurements
Lab. Supp. Component Sampling method Measuring method Unit A R Par. Ac Interval Date of start Date of end
1 1 SO2 [sulphur dioxide] - UVFL [UV-fluorescence] µg/m3 No Yes 0 No 1h 2006-03-01 2014-08-31
1 1 SO2 [sulphur dioxide] - UVFL [UV-fluorescence] µg/m3 No No 0 No 30min 1992-06-01 2000-12-31
1 1 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m3 No Yes 0 No 1h 2006-03-01 2014-08-31
1 1 NO [nitrogen monoxide] - CHLM [chemiluminescence] µg/m3 No No 0 No 30min 1992-06-01 2000-12-31
1 1 NO2 [nitrogen dioxide] - CHLM [chemiluminescence] µg/m3 No Yes 0 No 1h 2006-03-01 2014-08-31
1 1 NO2 [nitrogen dioxide] - CHLM [chemiluminescence] µg/m3 No No 0 No 30min 1992-06-01 2000-12-31
1 1 NOx [nitrogen oxides] - CHLM [chemiluminescence] µg/m3 No Yes 0 No 1h 2006-03-01 2014-08-31
1 1 NOx [nitrogen oxides] - CHLM [chemiluminescence] µg/m3 No No 0 No 30min 1992-06-01 2000-12-31
1 1 PM10 [particles PM10] - RADIO [radiometry - beta ray absorption] µg/m3 No No 0 No 1h 2006-03-01 2010-06-14
1 1 SPM [suspended particulate matter] - RADIO [radiometry - beta ray absorption] µg/m3 No No 0 No 30min 1992-06-01 2000-12-31
1 1 BZN [Benzene] - GC-FID [gas chromatography - flame-ionization detection] µg/m3 No Yes 0 No 1h 2006-03-01 2014-08-31
1 1 TLN [toluene] - GC-FID [gas chromatography - flame-ionization detection] µg/m3 No Yes 0 No 1h 2006-03-01 2014-08-31
1 1 EBZN [ethylbenzene] - GC-FID [gas chromatography - flame-ionization detection] µg/m3 No Yes 0 No 1h 2006-03-01 2014-08-31
1 1 MPXY [m,p-xylene] - GC-FID [gas chromatography - flame-ionization detection] µg/m3 No Yes 0 No 1h 2006-03-01 2014-08-31
1 1 OXY [o-xylene] - GC-FID [gas chromatography - flame-ionization detection] µg/m3 No Yes 0 No 1h 2006-03-01 2014-08-31
1 1 WV [wind velocity] - U-SONIC [ultrasonic anemometer] m/s No Yes 0 No 1h 2006-03-01 2014-08-31
1 1 WD [wind direction] - U-SONIC [ultrasonic anemometer] deg No Yes 0 No 1h 2006-03-01 2014-08-31
1 1 p [atmospheric pressure] - APRESS [atmospheric pressure measurement] hPa No Yes 0 No 1h 2006-03-01 2010-08-31
1 1 h [relative air humidity (h. of air)] - CAP [capacitance sensor] % No Yes 0 No 1h 2006-03-01 2014-08-31
1 1 T2m [temperature 2m above terrain] - PT100 [resistance method] K No Yes 0 No 1h 2006-03-01 2014-08-31
List of laboratories
Laboratory number1 ELMEP

Tel.: 315 712 206
Fax:.:
E-mail: formanek@iol.cz
List of data suppliers
Supplier number1
Wichtetleho 809
278 52 Kralupy nad Vltavou
Tel.: 315 718 713
Fax:.: 315 713 809
E-mail: Klara.Klouckova@crc.cz