Information about air quality in the Czech Republic
Measuring programme table
Updated: 2015-05-25 16:23 CEST
Basic data | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Code: | MOLSA | |||||||||||
Old ISKO number: | 1197 | |||||||||||
Locality: | Olomouc-Smeralova | |||||||||||
Type of measuring programme: | Automated measuring program | |||||||||||
Measuring networks: | ||||||||||||
Administrator | ||||||||||||
ZU-Ostrava Partyzánské nám. 7 702 00 Ostrava 1 |
Tel.: 596 200 361 | |||||||||||
Fax:.: 596 118 661 | ||||||||||||
E-mail: hyglab.ov@zuova.cz | ||||||||||||
Target of the measuring programme | ||||||||||||
Evaluation of the effect on the population health | ||||||||||||
Cover | ||||||||||||
not defined | ||||||||||||
Note | ||||||||||||
Stanice je umístěna na Šmeralově ulici v areálu VŠ kolejí. | ||||||||||||
Measurements | ||||||||||||
Lab. | Supp. | Component | Sampling method | Measuring method | Unit | A | R | Par. | Ac | Interval | Date of start | Date of end |
1 | 1 | PM2,5 [fine particles PM2.5] | - | OPEL [optoelectronic method] | µg/m3 | No | Yes | 0 | No | 1h | 2015-01-01 | |
1 | 1 | PM10 [particles PM10] | - | OPEL [optoelectronic method] | µg/m3 | No | Yes | 0 | No | 1h | 2015-01-01 | |
1 | 1 | WV [wind velocity] | - | OPEL [optoelectronic method] | m/s | No | Yes | 0 | No | 1h | 2015-01-01 | |
1 | 1 | WD [wind direction] | - | OPEL [optoelectronic method] | deg | No | Yes | 0 | No | 1h | 2015-01-01 | |
1 | 1 | h [relative air humidity (h. of air)] | - | CAP [capacitance sensor] | % | No | Yes | 0 | No | 1h | 2015-01-01 | |
1 | 1 | T2m [temperature 2m above terrain] | - | PT100 [resistance method] | K | No | Yes | 0 | No | 1h | 2015-01-01 | |
2 | 1 | SO2 [sulphur dioxide] | - | UVFL [UV-fluorescence] | µg/m3 | No | No | 0 | No | 30min | 1995-01-01 | 2008-05-31 |
2 | 1 | NO [nitrogen monoxide] | - | CHLM [chemiluminescence] | µg/m3 | No | No | 0 | No | 30min | 1995-09-01 | 2010-02-16 |
2 | 1 | NO2 [nitrogen dioxide] | - | CHLM [chemiluminescence] | µg/m3 | No | No | 0 | No | 30min | 1995-01-05 | 2010-02-16 |
2 | 1 | NOx [nitrogen oxides] | - | CHLM [chemiluminescence] | µg/m3 | No | No | 0 | No | 30min | 1995-01-05 | 2010-02-16 |
2 | 1 | O3 [ozone] | - | UVABS [UV-absorption] | µg/m3 | No | No | 0 | No | 30min | 1995-01-01 | 2010-02-16 |
2 | 1 | PM10 [particles PM10] | - | TEOM [tapered element oscillating microbalance (TEOM)] | µg/m3 | No | Yes | 0 | No | 30min | 1995-01-01 | 2014-09-30 |
List of laboratories | ||||||||||||
Laboratory number1 | KHS-Ostrava Partyzánské náměstí 7 70200 Ostrava 1 |
Tel.: 596 200 361 | ||||||||||
Fax:.: 596 118 661 | ||||||||||||
E-mail: hyglab.ov@zuova.cz | ||||||||||||
Laboratory number2 | ZU se sidlem v Ostravě-CHL Wolkerova 6 77900 Olomouc |
Tel.: 585719111 | ||||||||||
Fax:.: 585719310 | ||||||||||||
E-mail: radko.hradil@zuova.cz | ||||||||||||
List of data suppliers | ||||||||||||
Supplier number1 | ZU se sidlem v Ostravě-CHL Wolkerova 6 77900 Olomouc |
Tel.: 585719111 | ||||||||||
Fax:.: 585719310 | ||||||||||||
E-mail: radko.hradil@zuova.cz |