Information about air quality in the Czech Republic

Measuring programme table

Updated: 2015-05-25 16:23 CEST


Basic data
Code: ALIB5
Old ISKO number: 1626
Locality: Praha 4-Libus
Type of measuring programme: Heavy metal in PM2.5
Measuring networks: National air pollution network
Administrator
ČHMÚ - Libuš CLI
Gen.Šišky 942
143 00 Praha 4 - Libuš
Tel.: 244033467
Fax:.: 241727935
E-mail: silhavy@chmi.cz
Target of the measuring programme
Cover
container (air-conditioned)
Note
Measurements
Lab. Supp. Component Sampling method Measuring method Unit A R Par. Ac Interval Date of start Date of end
1 1 PM2,5 [fine particles PM2.5] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] GRV [gravimetry] µg/m3 Yes No 0 Yes 1d/2d 2010-01-01
1 2 V [vanadium] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 No 1d/2d 2011-01-01
1 2 Cr [chromium] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 No 1d/2d 2011-01-01
1 2 Mn [manganese] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 No 1d/2d 2010-01-01
1 2 Fe [iron] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 No 1d/2d 2011-01-01
1 2 Co [cobalt] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 No 1d/2d 2011-01-01
1 2 Ni [nickel] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 Yes 1d/2d 2010-01-01
1 2 Cu [copper] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 No 1d/2d 2010-01-01
1 2 Zn [zinc] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 No 1d/2d 2011-01-01
1 2 As [arsenic] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 Yes 1d/2d 2010-01-01
1 2 Se [selenium] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 No 1d/2d 2011-01-01
1 2 Cd [cadmium] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 Yes 1d/2d 2010-01-01
1 2 Pb [lead] LVSauto2.3 [LVS - automatic filter change 2,3 m3/h] ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 Yes 1d/2d 2010-01-01
1 2 PM2,5 [fine particles PM2.5] - GRV [gravimetry] µg/m3 No No 0 No 1d/2d 2005-01-01 2007-12-31
1 2 PM2,5 [fine particles PM2.5] - GRV [gravimetry] µg/m3 Yes No 0 Yes 1d/3d 2008-01-01 2009-12-31
1 2 Mn [manganese] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 No 1d/2d 2005-01-01 2007-12-31
1 2 Mn [manganese] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 Yes 1d/3d 2008-01-01 2009-12-31
1 2 Ni [nickel] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 No 1d/2d 2005-01-01 2007-12-31
1 2 Ni [nickel] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 Yes 1d/3d 2008-01-01 2009-12-31
1 2 Cu [copper] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 No No 0 No 1d/2d 2005-01-01 2007-12-31
1 2 Cu [copper] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 Yes 1d/3d 2008-01-01 2009-12-31
1 2 As [arsenic] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 No 1d/2d 2005-01-01 2007-12-31
1 2 As [arsenic] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 Yes 1d/3d 2008-01-01 2009-12-31
1 2 Cd [cadmium] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 No 1d/2d 2005-01-01 2007-12-31
1 2 Cd [cadmium] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 Yes 1d/3d 2008-01-01 2009-12-31
1 2 Pb [lead] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 No 1d/2d 2005-01-01 2007-12-31
1 2 Pb [lead] - ICP-MS [inductively coupled plasma - mass spectrometry] ng/m3 Yes No 0 Yes 1d/3d 2008-01-01 2009-12-31
List of laboratories
Laboratory number1 ČHMÚ-CLI TK
Gen.Šišky 942
143 00 Praha 4 - Libuš
Tel.: 244033451
Fax:.:
E-mail: novakj@chmi.cz
List of data suppliers
Supplier number1 CHMI-CLI TK
Generála Šišky 942
143 00 Praha 4 - Libuš
Tel.: 244 033 484
Fax:.:
E-mail: lucie.sedlakova@chmi.cz
Supplier number2 ČHMÚ-CLI TK
Generála Šišky 942
14300 Praha 4 - Libuš
Tel.: 244033482
Fax:.:
E-mail: rychliks@chmi.cz