logo ČHMÚ

ZSNVA, Stitna n.Vlari

Index Back

Situation in the year: 2005


Basic data
Code of the measuring programme in the given locality: ZSNVA
Old ISKO number: 1134
Locality: Stitna n.Vlari
Type of measuring programme: Automated measuring program
Measuring networks: EUROAIRNET 
Address
Administrator ČHMÚ - pob.Brno
Kroftova 43
Mgr. Robert  Skeřil   
61667  Brno
Tel:541421046
Fax:541421018
E-mail: robert.skeril@chmi.cz
Supplementary data
Target of the measurement programme: Evalution of total level of concentrations beckground
Place description
Vrcholová partie Bílých Karpat. CHKO
Measurement
Lab. = Laboratory, Sup. = data supplier, A = authorization, R = data available in the real time regime, Par. = parallel measurement
Lab. Sup. Component Method Unit A R Par. Interval Date of start Date of end
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No Yes 0 1h 01.01.2004  
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No No 0 30min 16.04.2003 31.12.2003 
1 1 GLRD [global radiation] TDM [temperature difference method] W/m2 No Yes 0 10min 01.01.2004  
1 1 h [relative air humidity (h. of air)] HAIR [hair hygrometer] % No No 0 30min 15.01.1994 31.12.2003 
1 1 h [relative air humidity (h. of air)] HAIR [hair hygrometer] % No Yes 0 1h 01.01.2004  
1 1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 No No 0 30min 15.01.1994 16.04.2003 
1 1 NOx [nitrogen oxides(oxides of nitrogen)] CHLM [chemiluminescence] µg/m3 No No 0 30min 15.01.1994 16.04.2003 
1 1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 No No 0 30min 15.01.1994 16.04.2003 
1 1 O3 [ozone] UVABS [UV-absorption] µg/m3 Yes Yes 0 1h 01.01.2004  
1 1 O3 [ozone] UVABS [UV-absorption] µg/m3 No No 0 30min 16.04.2003 31.12.2003 
1 1 PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 No No 0 30min 03.10.1994 16.04.2003 
1 1 RAD_A [RAD_A] RAD [dosimeter] uSv/hod No Yes 0 10min 15.10.2004  
1 1 RAD_A [RAD_A] RAD [dosimeter] uSv/hod No Yes 0 1h 15.10.2004  
1 1 RAD_B [RAD_B] RAD [dosimeter] uSv/hod No Yes 0 10min 15.10.2004  
1 1 RAD_B [RAD_B] RAD [dosimeter] uSv/hod No Yes 0 1h 15.10.2004  
1 1 RAD_C [RAD_C] RAD [dosimeter] uSV/hod No Yes 0 10min 15.10.2004  
1 1 RAD_C [RAD_C] RAD [dosimeter] uSV/hod No Yes 0 1h 15.10.2004  
1 1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 No No 0 30min 15.01.1994 16.04.2003 
1 1 SPM [suspended particulate matter] RADIO [radiometry - beta ray absorption] µg/m3 No No 0 30min 15.01.1994 02.10.1994 
1 1 T [temperature (unspecificated)] PT100 [resistance method] K No No 0 30min 15.01.1994 31.12.2003 
1 1 T2m [temperature 2m above terrain] PT100 [resistance method] K No Yes 0 1h 01.01.2004  
1 1 WD [wind direction] OPEL [optoelectronic method] deg No Yes 0 10min 01.01.2004  
1 1 WD [wind direction] OPEL [optoelectronic method] deg No No 0 30min 15.01.1994 31.12.2003 
1 1 WD [wind direction] OPEL [optoelectronic method] deg No Yes 0 1h 01.01.2004  
1 1 WDm [30 min wind direction maximum] OPEL [optoelectronic method] deg No Yes 0 10min 01.01.2004  
1 1 WDm [30 min wind direction maximum] OPEL [optoelectronic method] deg No Yes 0 1h 01.01.2004  
1 1 WV [wind velocity] OPEL [optoelectronic method] m/s No Yes 0 1h 01.01.2004  
1 1 WV [wind velocity] OPEL [optoelectronic method] m/s No No 0 30min 15.01.1994 31.12.2003 
1 1 WV [wind velocity] OPEL [optoelectronic method] m/s No Yes 0 10min 01.01.2004  
1 1 WVm [30min wind velocity maximum] OPEL [optoelectronic method] m/s No Yes 0 10min 01.01.2004  
1 1 WVm [30min wind velocity maximum] OPEL [optoelectronic method] m/s No Yes 0 1h 01.01.2004  

 

List of laboratories
Laboratory number 1 ČHMÚ-pob.Brno-AMS
Kroftova 43
Josef  Sviták   
61667  Brno
Tel: 541421045
Fax:
E-mail: josef.svitak@chmi.cz

 

List of data suppliers
Supplier number 1
Kroftova 43
Mgr. Robert  Skeřil   
61667  Brno
Tel: 541421046
Fax: 541421108
E-mail: robert.skeril@chmi.cz

Index Back
Valid XHTML 1.0!