logo ČHMÚ

HSRLR, Serlich

Index Back

Situation in the year: 2004


Basic data
Code of the measuring programme in the given locality: HSRLR
Old ISKO number: 88
Locality: Serlich
Type of measuring programme: Throughfall
Measuring networks:  
Address
Administrator VULHM
Jíloviště-Strnady
Ing. Z.  Lachmanová   
15604  Praha 5
Tel: 257892231
Fax: 257921444
E-mail: lachmanova@vulhm.cz
Data supplier Výzkumný ústav lesního hospodářství a myslivosti
Jíloviště-Strnady
Ing. Z.  Lachmanová   
15604  Praha 5
Tel: 257892231
Fax: 257921444
E-mail: lachmanova@vulhm.cz
Supplementary data
Target of the measurement programme: stanovení koncentrace srážek a atmosférické depozice
Place description
Stanice je umístena 150m od Masarykovy boudy.
Measurement
Lab. = Laboratory, A = authorization, R = data available in the real time regime, Par. = parallel measurement
Lab. Component Method Unit A R Par. Interval Date of start Date of end
1 rain [precipitation amount] ODMV [odměrný válec] mm Yes Yes 0 irregular/irregular 01.01.2002  
1 cond [conductivity] PTELDA [conductometry (platinum electrode)] µS/cm Yes Yes 0 irregular/irregular 01.01.2002  
1 pH [pH] pH meter [pH meter] - Yes Yes 0 irregular/irregular 01.01.2002  
1 Na [sodium ion] ICP-OES [inductively coupled plasma - optical emission spectroscopy] ug/l Yes Yes 0 irregular/irregular 01.01.2002  
1 K [potassium ion] ICP-OES [inductively coupled plasma - optical emission spectroscopy] ug/l Yes Yes 0 irregular/irregular 01.01.2002  
1 Mg [magnesium ion] ICP-OES [inductively coupled plasma - optical emission spectroscopy] ug/l Yes Yes 0 irregular/irregular 01.01.2002  
1 Ca [calcium ion] ICP-OES [inductively coupled plasma - optical emission spectroscopy] ug/l Yes Yes 0 irregular/irregular 01.01.2002  
1 NH4 [ammonium particles] SFA [spectrophotometry] ug/l Yes Yes 0 irregular/irregular 01.01.2002  
1 NO3 [nitrate - particles] IC [ion chromatography] ug/l Yes Yes 0 irregular/irregular 01.01.2002  
1 Cl [chlorine ion] IC [ion chromatography] ug/l Yes Yes 0 irregular/irregular 01.01.2002  
1 SO4 [sulphate - particles] IC [ion chromatography] ug/l Yes Yes 0 irregular/irregular 01.01.2002  
1 Al [aluminium ion] ICP-OES [inductively coupled plasma - optical emission spectroscopy] ug/l Yes Yes 0 irregular/irregular 01.01.2002  
1 Fe [iron ion] ICP-OES [inductively coupled plasma - optical emission spectroscopy] ug/l Yes Yes 0 irregular/irregular 01.01.2002  
1 F [fluorine ion] ISE-I. [ion selective electrod] ug/l Yes Yes 0 irregular/irregular 01.01.2002  
1 Zn [zinc ion] ICP-OES [inductively coupled plasma - optical emission spectroscopy] ug/l Yes Yes 0 irregular/irregular 01.01.2002  
1 Mn [manganese ion] ICP-OES [inductively coupled plasma - optical emission spectroscopy] ug/l Yes Yes 0 irregular/irregular 01.01.2002  
1 Cu [copper ion] ICP-OES [inductively coupled plasma - optical emission spectroscopy] mg/l Yes Yes 0 irregular/irregular 01.01.2002  
1 Cox [oxidovatelný uhlík] TITRACE [TITRACE] mg/l Yes Yes 0 irregular/irregular 01.01.2002  
1 P-sum [phosphorus sum] SFA [spectrophotometry] mg/l Yes Yes 0 irregular/irregular 01.01.2002  
1 alk. [alkalinity] UNKN [unknown method] mmol/l Yes Yes 0 irregular/irregular 01.01.2002  
 
List of laboratories
Laboratory number 1Zkušební laboratoře VÚLHM
Jíloviště-Strnady 136
Ing. Oldřich  Přibyl  p.
15604  Praha 5
Tel: 257892279
Fax: 257921444
E-mail: pribyl@vulhm.cz

IndexBack