logo ČHMÚ

OCGOA, Czarna Gora

Index Back

Situation in the year: 2004


Basic data
Code of the measuring programme in the given locality: OCGOA
Old ISKO number: 1432
Locality: Czarna Gora
Type of measuring programme: Automated measuring program
Measuring networks: Black triangle 
Address
Administrator Zaklad Ochrony Srodowiska ATMON
Ul. Wolnosci 150
     
  JELENIA GORA
Tel:+4875 7526082
Fax:+4875 7678858
E-mail:
Data supplier WIOS' Jelenia Góra
Ul. Warszavska 28
R.M. Kusztal     
  Jelenia Góra
Tel: +4875 7649445
Fax: +4875 7648989
E-mail:
Supplementary data
Target of the measurement programme: Evalution of total level of concentrations beckground
Place description
Úbočí Černé hory (n. v. 1205m n.m.). Smrkový les - nejblíže JZZ cca 5m.
Measurement
Lab. = Laboratory, A = authorization, R = data available in the real time regime, Par. = parallel measurement
Lab. Component Method Unit A R Par. Interval Date of start Date of end
1 CO [carbon monoxide] IRABS [IR corel. absorption spectrometry] µg/m3 Yes Yes 0 30min 01.01.1997 31.12.2003 
1 GLRD [global radiation] TDM [temperature difference method] W/m2 Yes Yes 0 30min 01.01.1998 31.12.2003 
1 h [relative air humidity (h. of air)] CAP [capacitance sensor] % Yes Yes 0 30min 01.01.1998 31.12.2003 
1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 1h 01.01.2004  
1 NO [nitrogen monoxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 30min 01.01.1997 31.12.2003 
1 NOx [nitrogen oxides(oxides of nitrogen)] CHLM [chemiluminescence] µg/m3 Yes Yes 0 30min 01.01.1997 23.12.1997 
1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 1h 01.01.2004  
1 NO2 [nitrogen dioxide] CHLM [chemiluminescence] µg/m3 Yes Yes 0 30min 01.01.1997 31.12.2003 
1 O3 [ozone] UVABS [UV-absorption] µg/m3 Yes Yes 0 1h 01.01.2004  
1 O3 [ozone] UVABS [UV-absorption] µg/m3 Yes Yes 0 30min 01.01.1997 31.12.2003 
1 p [atmospheric pressure] APRESS [atmospheric pressure measurement] hPa Yes Yes 0 30min 01.01.1998 31.12.2003 
1 PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 1h 01.01.2004  
1 PM10 [suspended particles (PM10 fraction)] RADIO [radiometry - beta ray absorption] µg/m3 Yes Yes 0 30min 01.01.1997 31.12.2003 
1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes Yes 0 30min 01.01.1997 31.12.2003 
1 SO2 [sulphur dioxide] UVFL [UV-fluorescence] µg/m3 Yes Yes 0 1h 01.01.2004  
1 T [temperature (unspecificated)] PT100 [resistance method] K Yes Yes 0 30min 01.01.1998 31.12.2003 
1 WD [wind direction] OPEL [optoelectronic method] deg Yes Yes 0 30min 01.01.1998 31.12.2003 
1 WV [wind velocity] ELMAG [electromagnetic method] m/s Yes Yes 0 30min 01.01.1998 31.12.2003 

 

List of laboratories
Laboratory number 1 Zaklad Ochrony Srodowiska ATMON
Ul. Wolnosci 150
     
  JELENIA GORA
Tel: +4875 7526082
Fax: +4875 7678858
E-mail:

Index Back
Valid XHTML 1.0!