Basic data | |||||||||
---|---|---|---|---|---|---|---|---|---|
Code of the measuring programme in the given locality: | CCBDA | ||||||||
Old ISKO number: | 1104 | ||||||||
Locality: | Ceske Budejovice | ||||||||
Type of measuring programme: | Automated measuring program | ||||||||
Measuring networks: | EUROAIRNET | ||||||||
Address | |||||||||
Administrator |
ČHMÚ - pob. Plzeň Mozartova 41 Ing. Tomáš Fory 323 00 Plzeň |
Tel:377256641 | |||||||
Fax:377237444 | |||||||||
E-mail: fory@chmi.cz | |||||||||
Data supplier |
ČHMÚ - pob. Plzeň Mozartova 41 Ing. Jan Hadinger 323 00 Plzeň |
Tel: 377256643 | |||||||
Fax: 377237444 | |||||||||
E-mail: hadinger@chmi.cz | |||||||||
Supplementary data | |||||||||
Target of the measurement programme: | Evalution of concentration in urban areas | ||||||||
Place description | |||||||||
Kontejner umístěn na travnatém prostranství mezi městskou zástavbou, asi 300m od pravého břehu Vltavy. | |||||||||
Measurement Lab. = Laboratory, A = authorization, R = data available in the real time regime, Par. = parallel measurement |
|||||||||
Lab. | Component | Method | Unit | A | R | Par. | Interval | Date of start | Date of end |
1 | BZN [benzene] | GCH-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | CO [carbon monoxide] | IRABS [IR corel. absorption spectrometry] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | CO [carbon monoxide] | IRABS [IR corel. absorption spectrometry] | µg/m3 | Yes | Yes | 0 | 30min | 07.09.1994 | 31.12.2003 |
1 | EBZN [ethylbenzene] | GCH-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | h [relative air humidity (h. of air)] | CAP [capacitance sensor] | % | Yes | No | 0 | 1h | 01.11.2004 | |
1 | MPXY [m,p-xylene] | GCH-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | NO [nitrogen monoxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | 30min | 28.03.1994 | 31.12.2003 |
1 | NOx [nitrogen oxides(oxides of nitrogen)] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | NOx [nitrogen oxides(oxides of nitrogen)] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | 30min | 28.03.1994 | 31.12.2003 |
1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | NO2 [nitrogen dioxide] | CHLM [chemiluminescence] | µg/m3 | Yes | Yes | 0 | 30min | 28.03.1994 | 31.12.2003 |
1 | OXY [o-xylene] | GCH-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | O3 [ozone] | UVABS [UV-absorption] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | O3 [ozone] | UVABS [UV-absorption] | µg/m3 | Yes | Yes | 0 | 30min | 07.09.1994 | 31.12.2003 |
1 | PM10 [suspended particles (PM10 fraction)] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | PM10 [suspended particles (PM10 fraction)] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | 30min | 24.10.1995 | 31.12.2003 |
1 | PM2,5 [fine suspended particles (PM2,5 fraction)] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | PM2,5 [fine suspended particles (PM2,5 fraction)] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | 30min | 01.05.2003 | 31.12.2003 |
1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | No | 0 | 10min | 01.01.2004 | |
1 | SO2 [sulphur dioxide] | UVFL [UV-fluorescence] | µg/m3 | Yes | Yes | 0 | 30min | 28.03.1994 | 31.12.2003 |
1 | SPM [suspended particulate matter] | RADIO [radiometry - beta ray absorption] | µg/m3 | Yes | Yes | 0 | 30min | 28.03.1994 | 23.10.1995 |
1 | TLN [toluene] | GCH-PID [gas chromatography - photo-ionization detection] | µg/m3 | Yes | No | 0 | 1h | 01.01.2004 | |
1 | T2m [temperature 2m above terrain] | PT100 [resistance method] | K | Yes | No | 0 | 1h | 01.11.2004 | |
1 | WD [wind direction] | U-SONIC [ultrasonic anemometer] | deg | Yes | No | 0 | 1h | 01.11.2004 | |
1 | WD [wind direction] | U-SONIC [ultrasonic anemometer] | deg | Yes | No | 0 | 10min | 01.11.2004 | |
1 | WDm [30 min wind direction maximum] | U-SONIC [ultrasonic anemometer] | deg | Yes | No | 0 | 1h | 01.11.2004 | |
1 | WV [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | Yes | No | 0 | 1h | 01.11.2004 | |
1 | WV [wind velocity] | U-SONIC [ultrasonic anemometer] | m/s | Yes | No | 0 | 10min | 01.11.2004 | |
1 | WVm [30min wind velocity maximum] | U-SONIC [ultrasonic anemometer] | m/s | Yes | No | 0 | 1h | 01.11.2004 |
List of laboratories | |||||||||
---|---|---|---|---|---|---|---|---|---|
Laboratory number 1 |
ČHMÚ - pob. Plzeň Mozartova 41 Ing. Tomáš Fory 323 00 Plzeň |
Tel: 377256641 | |||||||
Fax: 377237444 | |||||||||
E-mail: fory@chmi.cz |