in the year: 1998



Basic data
Station number: 1188
Station name: Trinec-Kosmos
Station type: stacionary - AMS
District: Frýdek-Místek
Institution: CHMI
Laboratory address
ČHMÚ - pob. Ostrava
RNDr.Z.Blažek
K myslivně 1
708 00 Ostrava-Poruba
Tel: 069/6900-240,218
Fax: 069/6910289
Impeachable worker address
ČHMÚ - pob. Ostrava
RNDr.Zdeněk Blažek
K myslivně 1
708 00 Ostrava-Poruba
Tel: 069/6900240,218
Fax: 069/6910289
Location
Geographics coordinates:latitude: 49° 40' 6" ;   longitude: 18° 40' 48"
Altitude: 320 m
Expletory data of station
Landscape: Plain
Scenery: Administrative, commercial built-up area, housing units
Representative: District (County) scale (0.5-4 km)
Purpose: Evaluation of concentration in urban areas
Verbal description placing
Stanice umístěna na volném prostranství sídlištního centra.
Registration
Date of establishment station: 01-01-1994 Date of termination station:
Pollutant
Method
Unit
Interval
Begin date
End date
SO2 (sulphur dioxide) UVFL (UV-fluorescence)ug/m^3 30 min 01-01-1994
NO (nitrogen monoxide) CHLM (chemiluminescence)ug/m^3 30 min 01-01-1994
NO2 (nitrogen dioxide) CHLM (chemiluminescence)ug/m^3 30 min 01-01-1994
O3 (ozone) UVABS (UV-absorption)ug/m^3 30 min 01-04-1996
NOx (nitrogen oxides(oxides of nitrogen)) CHLM (chemiluminescence)ug/m^3 30 min 01-01-1994
SPM (suspended particulate matter) RADIO (radiometry - beta ray absorption)ug/m^3 30 min 01-01-199421-01-1997
PM10 (PM 10 particulate matter 10) RADIO (radiometry - beta ray absorption)ug/m^3 30 min 22-01-1997
WV (wind velocity) ELMAG (electromagnetic method)m/s 30 min 01-01-1994
WD (wind direction) ELMAG (electromagnetic method)deg 30 min 01-01-1994
h (relative air humidity (h. of air)) CAP (capacitance sensor)% 30 min 01-04-1996
T2m (temperature 2m above terrain) PT100 (resistance method)K 30 min 01-04-1996